Core Features | Description |
Dual-Function Detection | Monitors both flow and temperature simultaneously, saving space on ships |
Dual Relay Outputs | 6A SPDT independent relays, configurable for low flow alarm, high temperature alarm, etc., enhancing ship system safety |
Superior Corrosion Resistance | 316L stainless steel or Hastelloy C-22 construction, resistant to seawater and salt spray |
No Moving Parts | All-welded design eliminates marine organism attachment and mechanical wear, reducing maintenance needs |
High Safety Rating | SIL 2 certification meets safety requirements for critical ship systems |
Wide Temperature/Pressure Range | Operating temperature: -73℃ to 454℃; pressure rating: up to 241 bar(g), suitable for various ship applications |
Performance Indicator | Parameter |
Safety Rating | SIL 2 (EN 61508), Cat 4 (EN 954-1), PLe (EN ISO 13849-1) |
Flow Measurement Accuracy | Liquids: ±0.5% reading or ±0.012m/s; Gases: ±2% setpoint velocity |
Repeatability | ±0.5% of reading |
Response Time | As low as 3 seconds |
Material Options | 316L stainless steel (standard), Hastelloy C-22 (corrosion-resistant), Titanium (special) |
Ingress Protection | NEMA 4X/IP67 (standard), IP69K (stainless steel version) |
Max Operating Pressure | 3500 psig (241 bar(g)) @ 21℃, derated with temperature increase |
MTBF(Mean Time Between Failures) | 180 years |